Product Overview
¡ñSelf-adhesive rubber bitumen membrane is elastomer (SBS) modified asphalt-based materials, polyethylene film, aluminum foil to the surface membrane material or (double-sided self-adhesive), the use of antifouling isolation layer PSA waterproofing membrane.
¡ñSelf-adhesion without bonding agent,torching.
¡ñGood rubber elasticity,and elongation
¡ñExcellent adhension bond
¡ñGood self-coalescence
¡ñSafe application,no pullution
¡ñExcellent waterproof and high strength
¡ñCorrosion resistance and ageing-resistance
¡ñApplicable to the industrial and civil buildings roof, basement, indoor, municipal works and reservoirs. Swimming Pool and the subway tunnel waterproofing. Also apply to wood and metal structure of the roof waterproofing works. Particularly applicable to the inappropriate use of fire to the oil, chemical plants, mills and grain storage and other waterproofing works.
Types and specifications :
- To the different surface materials are divided into three types : PE (polyethylene surface) applicable to non-exposed waterproofing; AL (foil) applied to the exposed waterproofing N (no membrane, that is double-sided self-adhesive) applicable to the auxiliary waterproofing
- Use function is exposed waterproofing (O) and non-exposed (I) waterproofing use of the two
Size£ºArea:20m210 m25 m2 Concession:920mm,1000mm Thick:1.2mm,1.5mm,2.0mm
Construction Techniques :
¡ñPrimary treatment : : base to be strong, dry, clean (no dust, no oil) has come to the forefront of leveling, Depression cracks and application of polymer cement mortar Finisher
¡ñBrushing primary treatment agent : Shing agent containers opened barrel after stirring first brush with neighboring nodes to the grassroots, corner or anywhere for brushing, and then brushing or spraying construction. Affixed to be uniform. After drying surface should be kept clean if pollution is dirty and should be re-coating, drying time to shop sticky roll.
¡ñProcessing nodes : the canopy groove (Gutter), Cracks, the Pan-water, the water export pipeline extending roof, Roof population should be "Roof Engineering Technical Specification" (GB50345-2004) of the processing, should be set up to strengthen additional layer or layers of the part should be in accordance with the regulations set.
¡ñSelf-adhesive membrane BRIEF
¡ñHorizontal brick : first at the grassroots level on a baseline pop, and then from low to high brick. Coil started at the same time, expose the isolation of paper. See baseline brick, sheet lap ¡Ý 50 mm width (full bonding), ¡Ý 50 mm (empty shops, sticky point, of the sticky). Know immediately after the rubber membrane Roller compaction
¡ñKnow vertical plane : vertical plane from low to high brick, side of the isolation of paper side kick. Ibid. Lap side width, immediately after brick with a rubber membrane Roller compaction.
¡ñCoil received head : first received treatment with sealant sealed, and then use the pressure of the metal fixed. Fixation screws and the top seam to seal.
¡ñConstruction inspection : Check whether all the self-adhesive membrane torn and damaged, bubbles, beading, openings. If defects, defects in the open, eliminate bubbles resume and expand in the above area, in a paste, the grantor tight compaction.
Èý¡¢Note
1¡¢Not to bring exposure of membrane-type exposure for the environment¡£
2¡¢Do not freeze the base self-adhesive membrane surface BRIEF
3¡¢Not in the water pollution and the high rate of grassroots construction.
4¡¢Self-adhesive membrane packaging and paper only in isolation before and Paving Stones when removed
5¡¢Sealant unused, it is necessary to promptly sealed containers wring close
6¡¢Other manufacturers supporting materials, untested, please do not use this product¡£
Storage and transport :
¡ñMaterials should be in dry, ventilated storage environment to prevent the sun and the rain. Different types and sizes were stacked membrane¡£
¡ñCoil should perpendicularly stacking height of more than five layers
¡ñUnder normal conditions, storage for a year (from the date of production)
¡ñHorizontal transport membrane should not tilt or crossover, Wang pressure
Products are mainly technical performance indicators : implementation of the standards JC840-1999
|
Surface materials |
PE |
AL |
N |
Impermeability |
Pressure£¬Mpa |
0.2 |
0.2 |
0.1 |
Keep time£¬min |
120, Impermeable |
30, Impermeable |
Degree heat |
- |
80¡æ£¬Heating2h,No sliding |
- |
Rally£¬N/5cm¡Ý |
130 |
100 |
- |
Elongation£¬%¡Ý |
450 |
200 |
450 |
Flexibility |
-20¡æ£¬20mm¡£3S£¬1800No cracks |
|
Shear Properties
N/mm |
Membrane and membrane¡Ý |
2.0Or bonding aspect fracture |
bonding aspect fracture |
Aluminum sheet¡Ý |
Stripping PerformanceN/mm¡Ý |
1.5Or bonding aspect fracture |
bonding aspect fracture |
Anti-perforation |
Water seepage |
Artificial Hou Processing |
Appearance |
-
|
No crack, no bubble |
-
|
Rally maintain rate¡£%¡Ý |
80 |
Flexibility |
-20¡æ£¬20mm¡£3S£¬1800 No crack, |
A self-adhesive membrane fetal standards implementation JC898-2002
Size |
¢ñÐÍ |
¢òÐÍ |
Thickness |
1.5 |
2 |
3 |
2 |
3 |
Impermeability pressure£¨30min£©Mpa¡Ý |
0.2 |
0.3 |
Degree heat¡æ |
PE¡¢S |
70,No sliding¡¢No runny¡¢Without dropping
80,No sliding¡¢No runny¡¢Without dropping |
AL |
Rally N/50mm¡Ý |
200 |
350 |
450 |
Lag time greatest elongation£¬%¡Ý |
30 |
Low gentle degrees£¬¡æ |
-20 |
-30 |
Artificial Hou Processing |
Rally maintain rate£¬% |
- |
80 |
Low gentle degrees£¬¡æ |
-10 |
-20 |