tuowang Color Wide polyvinyl chloride (pvc) waterproofing membrane is a high performance
polymer waterproofing materials, in PVC resin as the main raw materials, the
incorporation of special agents and anti-aging components. using advanced
equipment, and advanced technology into production. Products have the tensile
strength, elongation, the rate of contraction of small, low-temperature
flexibility, and long service life characteristics. 1.05m,2.05,2.10m products
width, thickness 0.8,1.0,1.2,1.5. 2.0mm (special specifications can be
customized), the product is stable, reliable, and convenient.
Product Performance :
1¡¢Long service life, resistance to aging and roofing material to be used in 20
years, the underground up to 50 years.
2¡¢Strong high tensile strength, elongation, heat treatment changes the small size
3¡¢Flexible hypothermia that meet environmental temperature change is good.
4¡¢Root penetration resistance, and will create green roofs.
5¡¢Anti-perforation good.
6¡¢Construction of convenience, welding, solid reliable environmental
pollution-free.
7¡¢Strong chemical resistance, apply special occasions.
8¡¢Good plasticity, corner detail treatment convenient and quick.
9¡¢Easy maintenance and low cost.
Construction Technology :
Ò»¡¢Roof Engineering(GB50207-2002)
1£®Construction of grassroots strength, thickness, Water rates, and other
indicators should be consistent with national norms design requirements before
proceeding with PVC waterproof membrane construction.¡¡¡¡
2£®Identify planning membrane Underground direction and order, waterproof layer on
the natural contours of the arrangement at the grassroots level. Formation
straight, not bent, in accordance with the requirements of the lap lap width,
size precision.
3£®According to a fixed method of choice for the fixed, such as : mechanical
fixation, full bonding method of bonding, fixed point, it should be tightly
sealed
4£®Waterproofing membrane surface welding lap site should wipe clean, dry lap width
of not less than 60mm, using hot air welding, welding and welding welding mouth
direction was 45 ¡ã angle, and welding Roller mouth equality and maintain a
distance of about 5mm. Welding side was due Luminance melts exudative, no
leakage of welding, welding jump, charred or welding is not strong, Welding may
not harm non-welded parts of the membrane.
5£®Coil received the first Department of metal pressure fixed, the largest nail
distance should not exceed 900mm with sealant sealed cement mortar is closed.¡¡
6£®The whole project site waterproof construction has been completed, a
comprehensive quality inspection with them.
¶þ¡¢Underground Engineering(0B50208-2002)
1£®Underground construction methods can be divided into defense posted outside
defense and foreign law within two stickers, According to GB50208 standard
specifications with different thickness of the PVC membrane and different
construction side Law, and adhere to the following general provisions :
2£®Construction of grassroots strength, thickness, Water rates and other indicators
should be consistent with national norms design requirements before proceeding
with PVC waterproof membrane construction.¡¡
3£®According to different parts of the waterproof reasonable choice method, the
concrete implementation of GB50208 standard.¡¡
4£®Coil lap width should be not less than 100mm. the upper and lower levels of
membrane seams should be staggered one-third of sheet width and the upper and
lower levels of membrane not perpendicular to each other Stones.¡¡
5£®Coil lap width should be not less than 100mm. the upper and lower levels of
membrane seams should be staggered one-third of the width roll joints to take
over the use of welding, of the single-lap weld width is not less than 10mm.
6£®PVC membrane laying ride should not have to sag, tension and breakage. The
inspection can only be confirmed after a process under construction.
Èý¡¢Tunnel project and special occasions use of the light of the implementation of
national construction norms or linked construction company providing guidance.
Product Specifications (implementation of the standards : GB12952-2003)
Size |
Name |
Specifications |
Results |
1 |
Tensile StrengthMpa |
¡Ý7.0 |
16.4/14.2£¨Longitudinal/Wang/Different£© |
2 |
Elongation at break%¡Ý |
¡Ý150 |
260/300 |
3 |
Heat Treatment dimensional changes¡Ü |
¡Ü2.0 |
0.4-0.6 |
4 |
Meander sexual hypothermia |
-20¡æ,No cracks |
No cracks |
5 |
Anti-permeability |
0.2Mpa,24hImpermeable |
Impermeable |
6 |
Anti-perforation |
Water seepage |
Water seepage |
7 |
Shear state of the bonding between the¡Ý2.0N/mm or Foreign fracture in joints |
Qualified |
8 |
Visual quality without bond bubble is not without holes |
Meet standards |
Thermal Aging 80¡æ¡À2¡æ168 |
Tensile strength relative rate of change% |
¡À20 |
+2/+2 |
Elongation at break relative rate of change% |
¡À20 |
-6/0 |
Meander sexual hypothermia |
-20¡æ,No cracks |
No cracks |
9 |
Water treatment |
|
Acid Treatment |
Alkali processing |
Salt |
Acid Treatment |
Alkali processing |
Salt |
Tensile strength relative rate of change% |
¡À20 |
¡À20 |
¡À20 |
-2/6 |
+3/-6 |
-11/-10 |
Elongation at break relative rate of change% |
¡À20 |
¡À20 |
¡À20 |
-1/-5 |
-8/-8 |
0/1 |
Meander sexual hypothermia |
-20¡æ,No cracks |
No cracks |